Real Time AC DC Motors Interview Questions with Answers PDF


1. What is the principle of motor?
Whenever a current carrying conductor is placed in an magnetic field it produce turning or twisting movement is called as torque.

2. Types of dc generator?
DC Generators are classified into two types 1)separatly excited DC generator
2)self excited DC generator, which is further classified into; 1)series 2)shunt and 3)compound(which is further classified into cumulative and differential).
AC DC Motor Electrical Interview Questions

3. Which motor has high Starting Torque and Staring current DC motor, Induction motor or Synchronous motor?
DC Series motor has high starting torque. We can not start the Induction motor and Synchronous motors on load, but can not start the DC series motor without load.

4. Define stepper motor. What is the use of stepper motor?
The motor which work or act on the applied input pulse in it, is called as stepper motor. This stepper motor is under the category of synchronous motor, which often does not fully depend of complete cycle. It likes to works in either direction related to steps. for this purpose it mainly used in automation parts.

5. What is 2 phase motor?
A two phase motor is a motor with the the starting winding and the running winding have a phase split. e.g;ac servo motor.where the auxiliary winding and the control winding have a phase split of 90 degree.

6. which type of A.C motor is used in the fan (ceiling fan, exhaust fan, padestal fan, bracket fan etc) which are find in the houses ?
Its Single Phase induction motor which mostly squirrel cage rotor and are capacitor start capacitor run.

7. Give two basic speed control scheme of DC shunt motor?
1. By using flux control method:in this method a rheostat is connected across the field winding to control the field current.so by changing the current the flux produced by the field winding can be changed, and since speed is inversely proportional to flux speed can be controlled
2.armature control method:in this method a rheostat is connected across armature winding by varying the resistance the value of resistive drop(IaRa) can be varied, and since speed is directly proportional to Eb-IaRa the speed can be controlled.


8. Difference between a four point starter and three point starter?
The shunt connection in four point starter is provided separately form the line where as in three point starter it is connected with line which is the drawback in three point starter.

9. What is the difference between synchronous generator & asynchronous generator?
In simple, synchronous generator supply's both active and reactive power but asynchronous generator(induction generator) supply's only active power and observe reactive power for magnetizing. This type of generators are used in windmills.

10. Why syn. generators are used for the production of electricity?
Synchronous machines have capability to work on different power factor (or say different imaginary power varying the field EMF. Hence syn. generators r used for the production of electricity.

11. Why is the starting current high in a DC motor?
In DC motors, Voltage equation is V=Eb-IaRa (V = Terminal voltage, Eb = Back emf in Motor, Ia = Armature current,Ra = Aramture resistance). At starting, Eb is zero. Therefore, V=IaRa, Ia = V/Ra ,where Ra is very less like 0.01ohm.i.e, Ia will become enormously increased.

12. What are the advantages of star-delta starter with induction motor?
The main advantage of using the star delta starter is reduction of current during the starting of the motor. Starting current is reduced to 3-4 times Of current of Direct online starting.(2). Hence the starting current is reduced , the voltage drops during the starting of motor in systems are reduced.

13. Why series motor cannot be started on no-load?
Series motor cannot be started without load because of high starting torque. Series motor are used in Trains, Crane etc.

14. Mention the methods for starting an induction motor?
The different methods of starting an induction motor
DOL:direct online starter
Star delta starter
Auto transformer starter
Resistance starter
Series reactor starter

15. what are Motor Generator Sets and explain the different ways the motor generator set can be used ? 
Motor Generator Sets are a combination of an electrical generator and an engine mounted together to form a single piece of equipment. Motor generator set is also referred to as a genset, or more commonly, a generator The motor generator set can used in the following different ways:
1.Alternating current (AC) to direct current (DC)
2.DC to AC
3.DC at one voltage to DC at another voltage
4.AC at one frequency to AC at another harmonically-related frequency

16. Which type of motor is used in trains, what is the rating of supply used explain Working principal?
Dc series is in the trains to get high starting torque while starting of the trains and operating voltage is 1500v dc.

17. What are the Application of DC Motors in Thermal Power Plant?
In thermal power plants dc motors are employed for certain control and critical emergency operations which are supplied by dedicated batteries. DC motors operate as backup drives for normal ac drive systems when ac power supply to the plant is lost.
In thermal power plant, the dc motors finds applications for performing control functions such as
Turbine governor motor
Governor limit setting
Motor operated rheostats
Emergency lubrication for the turbines (main, boiler feed pumps)
Generator (H2 oil seal).
DC motor operated valves

DC motors employed in thermal plants are classified in to two types based on the type of application.

DC motors carrying out Control function
Dc motors carrying out Emergency function

Control functions:This category consists of the turbine governor motor, governor limiting setting, motor operated rheostats, etc. These motors are small, about 1/8 hp or less. They are operated quite infrequently for short duration.

Emergency functions:This category consists of turbine-generator emergency (lubrication) bearing oil pumps and emergency seal oil pumps. Such pumps may also be provided for steam turbine drives of feedwater pumps, fans, and other large loads. The lack of lubrication during a shutdown without ac power will ruin the linings of the bearings and damage the shaft.
Hydrogen seal oil pump is provided to prevent the escaping of hydrogen (for large turbine-generators hydrogen cooling is provided for efficient cooling) from the casing by providing a tight seal with high pressure oil

18. What are the Advantages & Disadvantages of Synchronous motors?
Advantage or Merits:
One of the major advantage of using synchronous motor is the ability to control the power factor. An over excited synchronous motor can have leading power factor and can be operated in parallel to induction motors and other lagging power factor loads thereby improving the system power factor.
In synchronous motor the speed remains constant irrespective of the loads. This characteristics helps in industrial drives where constant speed is required irrespective of the load it is driving. It also useful when the motor is required to drive another alternator to supply at a different frequency as in frequency changes.
Synchronous motors can be constructed with wider air gaps than induction motors which makes these motors mechanically more stable.
In synchronous motors electro-magnetic power varies linearly with the voltage.
Synchronous motors usually operate with higher efficiencies ( more than 90%) especially in low speed and unity power factor applications compared to induction motors

Disadvantages or Demerits:
Synchronous motors requires dc excitation which must be supplied from external sources.
Synchronous motors are inherently not self starting motors and needs some arrangement for its starting and synchronizing.
The cost per kW output is generally higher than that of induction motors.
These motors cannot be used for variable speed applications as there is no possibility of speed adjustment unless the incoming supply frequency is adjusted (Variable Frequency Drives).
Synchronous motors cannot be started on load. Its starting torque is zero.
These motors have tendency to hunt.
When loading on the synchronous motor increases beyond its capability, the synchronism between rotor and stator rotating magnetic field is lost and motor comes to halt.
Collector rings and brushes are required resulting in increase in maintenance.
Synchronous motors cannot be useful for applications requiring frequent starting or high starting torques required.

Latest AC DC Motors Interview Questions for freshers and Experienced pdf

Interview Questions On Alternator – Electrical engineering interview Questions and Answers



Real Time Alternator Interview Questions with Answers PDF

1. What are the two types of turbo-alternators ?
 Vertical and horizontal.

2. How do you compare the two ?
Vertical type requires less floor space and while step bearing is necessary to carry the weight of the moving element, there is very little friction in the main bearings. The horizontal type requires no step bearing, but occupies more space.
Alternator Questions and answers

3. What is step bearing ?
It consists of two cylindrical cast iron plates which bear upon each other and have a central recess between them. Suitable oil is pumped into this recess under considerable pressure.

4. What is direct-connected alternator ?
One in which the alternator and engine are directly connected. In other words, there is no intermediate gearing such as belt, chain etc. between the driving engine and alternator.

5. What is the difference between direct-connected and direct-coupled units ?
In the former, alternator and driving engine are directly and permanently connected. In the latter case, engine and alternator are each complete in itself and are connected by some device such as friction clutch, jaw clutch or shaft coupling.

6. Can a d.c. generator be converted into an alternator ? If yes then how ?
Yes. A DC generator can be converted into an alternator. By providing two collector rings on one end of the armature and connecting these two rings to two points in the armature winding 180° apart.

8. Would this arrangement result in a desirable alternator ?
No


9. How is a direct-connected exciter arranged in an alternator ?
The armature of the exciter is mounted on the shaft of the alternator close to the spider hub. In some cases, it is mounted at a distance sufficient to permit a pedestal and bearing to be placed between the exciter and the hub.

10. Any advantage of a direct-connected exciter ?
Yes, economy of space.

Latest Synchronous Alternator Interview Questions for freshers and Experienced pdf

15 TOP Synchronous Generator - Electrical Engineering Questions and Answers



Real Time Synchronous Generator Interview Questions with Answers PDF

1. Why syn. generators are used for the production of electricity?
synchronous machines have capability to work on different power factor(or say different imaginary power varying the field emf. Hence syn. generators are used for the production of electricity.

2. What is the difference between synchronous generator & asynchronous generator?
In simple, synchronous generator supply’s both active and reactive power but asynchronous generator(induction generator) supply’s only active power and observe reactive power for magnetizing.This type of generators are used in windmills.
Synchronous Generator Interview Questions

3. 1 ton is equal to how many watts?
1 ton = 12000 BTU/hr and to convert BTU/hr to horsepower, 12,000 * 0.0003929 = 4.715 hp therefore 1 ton = 4.715*.746 = 3.5 KW.

4. Enlist types of dc generator?
D.C.Generators are classified into two types 1)separatly exicted d.c.generator 2)self exicted d.c.generator, which is further classified into;1)series 2)shunt and 3)compound(which is further classified into cumulative and differential).

5. What is Automatic Voltage regulator(AVR)?
AVR is an abbreviation for Automatic Voltage Regulator.It is important part in Synchronous Generators, it controls theoutput voltage of the generator by controlling its excitation current. Thus it can control the output Reactive Power of the Generator.

6. What is an exciter and how does it work?
There are two types of exciters, static exciter and rotory exciter.purpose of excitor is to supply the excitation dc voltage to the fixed poles of generator.Rotory excitor is an additional small generator mounted on the shaft of main generator. if it is dc generator, it will supply dc to the rotory poles through slip ring and brushes( conventional alternator). if it is an ac excitor, out put of ac excitor is rectified by rotating diodes and supply dc to main fixed poles.ac excitor is the ac generator whose field winding are stationary and armature rotates. initial voltage is built up by residual magnetism.It gives the starting torque to the generator.

7. Difference between a four point starter and three point starter?
The shunt connection in four point stater is provided separately form the line where as in three point stater it is connected with line which is the drawback in three point stater


8. Why use the VCB at High Transmission System ? Why can’t use ACB?
Actually the thing is vacuum has high arc queching property compare to air because in VCB ,the die electric strengths equal to 8 times of air . That y always vaccum used as inHT breaker and air used as in LT .

9. What is the difference between surge arrestor and lightning arrestor?
LA is installed outside and the effect of lightning is grounded,where as surge arrestor installed inside panels comprising of resistors which consumes the energy and nullify the effect of surge.

10. What will happen when power factor is leading in distribution of power?
If their is high power factor, i.e if the power factor is close to one:
1.losses in form of heat will be reduced,
2.cable becomes less bulky and easy to carry, and very cheap to afford, &
3. it also reduces over heating of tranformers.

11. Whats the one main difference between UPS & inverter ? And electrical engineering & electronics engineering ?
uninterrupt power supply is mainly use for short time . means according to ups VA it gives backup. ups is also two types : on line and offline . online ups having high volt and amp for long time backup with with high dc voltage.but ups start with 12v dc with 7 amp. but inverter is startwith 12v,24,dc to 36v dc and 120amp to 180amp battery with long time backup.

12. What is 2 phase motor?
A two phase motor is a motor with the the starting winding and the running winding have a phase split. e.g;ac servo motor.where the auxiliary winding and the control winding have a phase split of 90 degree.

13. Advantages of vvvf drives over non vvvf drives for EOT cranes?
1.smooth start and stop.
2.no jerking of load.
3.exact posiitoning
4.better protection for motor.
5.high/low speed selection.
6.reliability of break shoe.
7.programmable break control.
8.easy circutry
9.reduction in controls
10.increases motor life

14. What is the significance of vector grouping in Power Transformers?
Every power transformer has a vector group listed by its manufacturer. Fundamentally it tells you the information about how the windings are connected (delta or wye) and the phace difference betweent the current and voltage. EG. DYN11 means Delta primary, Wye Secondry and the current is at 11 o clock reffered to the voltage.

15. Which type of A.C motor is used in the fan (ceiling fan, exhaust fan, padestal fan, bracket fan etc) which are find in the houses ?
Its Single Phase induction motor which mostly squirrel cage rotor and are capacitor start capacitor run.

Latest Synchronous Generator Interview Questions for freshers and Experienced pdf

110 TOP Synchronous Motors Multiple choice Questions and Answers pdf




Real Time Synchronous Motors Online Quiz Questions and Answers

=> Also Read Synchronous Motors Interview Questions
1. Synchronous motors are generally not self-starting because
(a) the direction of rotation is not fixed
(b) the direction of instantaneous torque reverses after half cycle
(c) startes cannot be used on these machines
(d) starting winding is not provided on the machines
Ans: b

2. In case one phase of a three-phase synchronous motor is short-circuited the motor will
(a)     not start
(b)     run at 2/3 of synchronous speed
(c) run with excessive vibrations
(d) take less than the rated load
Ans: a
Synchronous Motors Online Quiz Questions
3. A pony motor is basically a
(a) small induction motor
(b) D.C. series motor
(c) D.C. shunt motor
(d) double winding A.C./D.C. motor
Ans: a


4. A synchronous motor can develop synchronous torque
(a) when under loaded
(b) while over-excited
(c) only at synchronous speed
(d) below or above synchronous speed
Ans: c

5.   A synchronous motor can be started by
(a) pony motor
(b) D.C. compound motor
(c) providing damper winding
(d) any of the above
Ans: d

6. A three-phase synchronous motor will have
(a) no slip-rings    
(b) one slip-ring
(c) two slip-rings  
(d) three slip-rings
Ans: c

7. Under which of the following conditions hunting of synchronous motor is likely to occur ?
(a) Periodic variation of load
(b) Over-excitation
(c) Over-loading for long periods
(d) Small and constant load
Ans: a

8. When the excitation of an unloaded salient pole synchronous motor suddenly gets disconnected
(a) the motor stops
(b) it runs as a reluctance motor at the same speed
(c) it runs as a reluctance motor at a lower speed
(d) none of the above
Ans: a

9. When V is the applied voltage, then the breakdown torque of a synchronous motor varies as
(a) V
(b) V312
(c) V2
(d) 1/V
Ans: a

10. The power developed by a synchronous motor will be maximum when the load angle is
(a) zero
(b) 45°
(c) 90°
(d) 120°
Ans: c


11. A synchronous motor can be used as a synchronous capacitor when it is
(a) under-loaded  
(b) over-loaded
(c) under-excited  
(d) over-excited
Ans: d

12. A synchronous motor is running on a load with normal excitation. Now if the load on the motor is increased
(a) power factor as well as armature current will decrease
(b) power factor as well as armature current will increase
(c) power factor will increase but armature current will decrease
(d) power factor will decrease and armature current will increase
Ans: d

13. Mostly, synchronous motors are of
(a) alternator type machines
(6) induction type machines
(c) salient pole type machines
(d) smooth cylindrical type machines
Ans: c

14. The synchronous motor is not inherently self-starting because
(a) the force required to accelerate the rotor to the synchronous speed in an instant is absent
(b) the starting device to accelerate the rotor to near synchronous speed is absent
(c) a rotating magnetic field does not have enough poles
(d) the rotating magnetic field is produced by only 50 Hz frequency currents
Ans: a

15. As the load is applied to a synchronous motor, the motor takes more armature current because
(a)     the increased load has to take more current
(b)     the rotor by shifting its phase backward causes motor to take more current
(c) the back e.m.f. decreases causing an increase in motor current
(d) the rotor strengthens the rotating field casuing more motor current
Ans: b

16. Synchronous motor always runs at
(a)     the synchronous speed
(b)     less than synchronous speed
(c) more than synchronous speed
(d) none of the above
Ans: a

17. An over-excited synchronous motor takes
(a) leading current
(b) lagging current
(c) both (a) and (b)
(d)     none of the above
 Ans: a

18. The working of a synchronous motor is similar to
(a) gear train arrangement
(b) transmission of mechancial power by shaft
(c) distribution transformer
(d) turbine
(e) none of the above
Ans: b

19. The minimum armature current of the synchronous motor corresponds to operation at
(a) zero power factor leading
(b) unity power factor
(c) 0.707 power factor lagging
(d) 0.707 power factor leading
Ans: b

20. In a synchronous motor, the magnitude of stator back e.m.f. Eb depends on
(a) d.c. excitation only
(b) speed of the motor
(c) load on the motor
(d) both the speed and rotor flux
Ans: a

21. If load (or torque) angle of a 4-pole synchronous motor is 6° electrical, its value in mechanical degrees is
(a) 2
(b) 3
(c) 4
(d) 6
Ans: b

22. For V-curves for a synchronous motor the graph is drawn between
(a) field current and armature current
(b) terminal voltage and load factor
(c) power factor and field current
(d)     armature current and power factor
Ans: a

23. The back e.m.f. of a synchronous motor depends on
(a) speed
(b) load
(c) load angle
(d) all of the above
Ans: c

24. A synchronous motor can operate at
(a) lagging power factor only
(6) leading power factor only
(c) unity power factor only
(d) lagging, leading and unity power factors
Ans: d

25. In a synchronous motor which loss varies with load ?
(a) Windage loss
(b) Bearing friction loss
(c) Copper loss    
(d) Core loss
Ans: c

26. A synchronous motor can be made self starting by providing
(a) damper winding on rotor poles
(b) damper winding on stator
(c) damper winding on stator as well as rotor poles
(d) none of the above
Ans: d

27. The oscillations in a synchronous motor can be damped out by
(a)     maintaining constant excitation
(b)     running the motor on leading power factors
(c) providing damper bars in the rotor pole faces
(d) oscillations cannot be damped
Ans: c

28. The shaft of synchronous motor is made of
(a) mild steel
(b) chrome steel
(c) alnico
(d) stainless steel
Ans: a

29. When the field of a synchronous motor is under-excited, the power factor will be
(a) leading
(b) lagging
(c) unity
(d) zero
Ans: b

30. The speed regulation of a synchronous motor is always
(a) 1%
(b) 0.5%
(c) positive
(d) zero
Ans: d

31. The percentage slip in case of a synchronous motor is
(a) 1%
(b) 100%
(c) 0.5%
(d) zero
Ans: d

32. The operating speed of a synchronous motor can be changed to new fixed value by
(a) changing the load
(b) changing the supply voltage
(c) changing frequency
(d) using brakes
Ans: c

33. A synchronous motor will always stop when
(a) supply voltage fluctuates
(b) load in motor varies
(c) excitation winding gets disconnected
(d) supply voltage frequency changes9885859805
Ans: c

34. riunting in a synchronous motor takes place
(a) when supply voltage fluctuates
(b) when load varies
(c) when power factor is unity
(d) motor is under loaded
Ans: b

35. When load on an over-excited or under excited synchronous*motor is increased, rate of change of its armature current as compared with that of power factor is
(a) more
(b) less
(c) equal
(d) twice
Ans: b

36. The rotor copper losses, in a synchronous motor, are met by
(a) d.c. source
(b) armature input
(c) motor input    
(d) supply lines
Ans: a

37. The maximum power developed in a synchronous motor occurs at a coupling angle of
(a) 30°
(b) 60°
(c) 90°
(d) 180°
Ans: c

38. When the stator windings are connected in such a fashion that the number of poles are made half, the speed of
the rotor of a synchronous motor
(a) remains same as the original value
(b) decreases to half the original value
(c) tends to becomes zero
(d)     increases to two times the original value
Ans: d

39. In which of the following motors the stator and rotor magnetic field rotate at the same speed ?
(a) Universal motor
(b) Synchronous motor
(c)     Induction motor
(d) Reluctance motor
Ans: b

40. Synchronsizingpower of a synchronous machine is
(a) direcly proportional to the synchronous reactance
(6) inversely proportional to the synchronous reactance
(a) equal to the synchronous reactance
(d) none of the above
Ans: b

41. Synchronous motors are
(a)     not-self starting
(b) self-starting
(c) essentially self-starting
(d) none of the above
Ans: a

42. The  standard full-load power factor ratings for synchronous motors are
(a)     zero or 0.8 leading
(b)     unity or 0.8 lagging
(c) unity or 0.8 leading
(d) unity or zero
Ans: c

43. A synchronous motor running with normal excitation adjusts to load increases essentially by increase in
(a) back e.m.f.
(b) armature current
(c) power factor    
(d) torque angle
Ans: b

44. A synchronous motor has better power factor as compared to that of an equivalent induction motor. This is mainly because
(a) synchronous motor has no slip
(b) stator supply is not required to produce magnetic field
(c) mechanical load on the rotor remains constant
(d) synchronous motor has large airgap
Ans: b

45. A synchronous motor working at leading power factor can be used as
(a)     voltage booster
(b)     phase advancer
(c) noise generator
(d) mechanical synchronizer
Ans: b

46. Slip rings are usually made of
(a) carbon or graphite
(b) brass or steel
(c) silver or gold
(d) copper or aluminium
Ans: b

47. An over excited synchronous motor is used for
(a) fluctuating loads
(b) variable speed loads
(c) low torque loads
(d)      power factor corrections
Ans: d

48. When the voltage applied to a synchronous motor is increased, which of the following will reduce ?
(a)     Stator flux
(b)     Pull in torque
(c) Both (a) and (b)
(d) None of the above
 Ans: d

51. The efficiency of a properly designed synchronous motor will usually fall in range
(a) 60 to 70%
(6) 75 to 80%
(c) 85 to 95%
(d) 99 to 99.5%
Ans: c

52. To limit the operating temperature an electrical machine should have proper
(a) voltage rating
(b) current rating
(c) power factor    
(d) speed
Ans: b

53. Slip-rings in a synchronous motor carry
(a) direct current
(b) alternating current
(c) no current
(d) all of the above
Ans: a

54. A synchronous machine with large air gap has
(a)     a higher value of stability limit
(6)     a small value of inherent regulation
(c) a higher synchronizing power which makes the machine less sensitive to load variations
(d) all of the above
Ans: d

55. The armature current of the synchronous motor has higher values for
(a)     high excitation only
(b)     low excitation only
(c) both (a) and (b)
(d) none of the above
Ans: c

56. In a synchronous motor running with fixed excitation, when the load is increased three times, its torque angle becomes approximately
(a) one-third
(b) twice
(c) thrice
(d) six times
(e) nine times
Ans: c

57. The angle between the rotating stator flux and rotor poles is called _____ angle.
(a) torque
(b) obtuse
(c) synchronizing
(d) power factor
Ans: a

58. Which of the following methods is used to start a synchronous motor ?
(a) Damper winding
(b) Star-delta starter
(c) Damper winding in conjunction with star-delta starter
(d) Resistance starter in the armature circuit
Ans: c

59. When the rotor speed, in a synchronous machine, becomes more than the synchronous speed during hunting, the damper bars develop
(a)     inductor motor torque
(b)     induction generator torque
(c) synchronous motor torque
(d) d.c. motor toque
(e) none of the above
Ans: b

60. An important advantage of a synchronous motor over wound round induction motor is that
(a) its power factor may be varied at will
(b) its speed is independent of supply frequency
(c) its speed may be controlled more easily
(d) none of the above
Ans: a

61. The mechanical displacement of the rotor with respect to the stator, in polyphase multipolar synchronous motors running at full load, is of the order of
(a) zero degree      
(b) two degrees
(c) five degrees    
(d) ten degrees
Ans: c

62. Power factor of a synchronous motor is unity when
(a) the armature current is maximum
(b) the armature current is minimum
(c) the armature current is zero
(d) none of the above
Ans: b

63. Change of D.C. excitation of a synchronous motor changes
(a) applied voltage of the motor
(b) motor speed
(c) power factor of power drawn by the motor
(d) any of the above
(e) all of the above
Ans: c

64. While starting a synchronous motor by induction motor action, field winding is usually
(a) connected to D.C. supply
(b) short-circuited by low resistance
(c) kept open-circuited
(d) none of the above
Ans: b

65. Which of the following motors will be used in electric clocks ?
(a) D.C. shunt motor
(b) D.C. series motor
(c) A.C. induction motor
(d) A.C. synchronous motor
Ans: d

66. If in a synchronous motor, driving mechanical load and drawing current at lagging power factor from constant
voltage supply, its field excitation is increased, then its power factor
(a) become more
(b) become less
(c) remain constant
(d) none of the above
Ans: b

67. A synchronous motor installed at the receiving end substation operates with such an excitation that it takes power
at lagging power factor. Now if the applied voltage of the synchronous motor goes down, the power factor of the
synchronous motor will
(a)     remain same  
(b)     go down
(c) improve
(d) none of the above
Ans: c

68. While starting a salient pole synchronous motor by induction motor action and connecting field discharge resistance across field, starting and accelerting torque is produced by
(a) induction motor torque in field winding
(b) induction motor torque in damper winding
(c) eddy current and hysteresis torque in pole faces
(d) reHetance motor torque due to saliency of the rotor
(e) all of the above methods
Ans: e

69.   Armature of a synchronous machine is
(a) of reducing number of slip rings on the rotor
(b) armature is associated with large power as compared to the field circuits
(c) of difficulty of providing high voltage insulation on rotor
(d) all of the above reasons
Ans: d

70. If excitation of a synchronous motor running with a constant load is decreased from its normal value, ignoring effects of armature reaction, it leads to
(a) increase in both armature current and power factor angle
(b) increase in back e.m.f. but decrease in armature current
(c) increase in both armature current and power factor which is lagging
(d) increase in torque angle but decrease in back e.m.f.
Ans: a

71. When a 3-phase synchronous generator is supplying a zero power factor lagging load, the armature field affects
the main field in the following way
(a) augments it directly
(b) directly opposes it
(c) cross-magnetises it
(d) none of the above
Ans: b

72. Stability of a synchronous machine
(a) decreases with increase in its excitation
(b) increases with increase in its excitation
(c) remains unaffected with increase in excitation
(d) any of the above
Ans: b

73. The power factor of a synchronous motor is better than that of induction motor because
(a) stator supply is relieved of responsibility of producing magnetic field
(b) mechanical load on the motor can be adjusted
(c) synchronous motor runs at synchronous speed
(d) synchronous motor has large air gap
Ans: a

74. If in a synchronous motor, driving a given mechanical load and drawing current at a leading power factor from
constant voltage supply its field excitation is increased, its power factor
(a)     will become more
(b)     will become less
(c) will remain unchanged
(d) none of the above.
Ans: b

75. A synchronous motor is running with normal excitation. When the load is increased, the armature current drawn
by it increases because
(a) speed of the motor is reduced
(b) power factor is decreased
(c) Eb (back e.m.f.) becomes less than V (applied voltage)
(d) Er (net resultant voltage) in armature is increased
(e) none of the above
Ans: d

76. If one-phase of a 3-phase synchronous motor is short-circuited, motor
(a) will refuse to start
(b) will overheat in spots
(c) will not come upto speed
(d)     will fail to pull into step
Ans: a

77. If the field circuit of an unloaded salientpole synchronous motor gets suddenly open-circuited, then
(a) it runs at a slower speed
(b) the motor stops
(c) it continues to run at the same speed
(d) it runs at a very high speed
Ans: b

78. In which of the following motors the stator and rotor fields rotate simultaneously ?
(a) D.C. motor
(b) Reluctance motor
(c) Universal motor
(d) Synchronous motor
(e) Induction motor
Ans: d

79. The speed of a synchronous motor
(a) increases as the load increases
(b) decreases as the load decreases
(c) always remains constant
(d) none of the above
 Ans: c

80. A rotory converter can also be run as a
(a)     d.c. shunt motor
(b)     d.c. series motor
(c) d.c. compound motor
(d) induction motor
(e) synchronous motor
Ans: e

81. The maximum speed variation in a 3-phase synchronous motor is
(a) 10 per cent      
(b) 6 per cent
(c) 4 per cent
(d) 2. per cent
(e) zero
Ans: e

82. Which of the following resistances can be measured by conducting insulation resistance test on a synchronous motor ?
(a) Phase to phase winding resistance
(b) Stator winding to earthed frame
(c) Rotor winding to earthed shaft
(d) All of the above
Ans: d

83. Due to which of the following reasons a synchronous motor fails to pull into synchronism after applying D.C. field
current ?
(a)     High field current
(b)     Low short circuit ratio
(c) High core losses
(d) Low field current
Ans: d

16.84. In a synchronous motor, the maximum power developed depends on all of the following except
(a) rotor excitation
(b) maximum value of coupling angle
(c) direction of rotation
(d) supply voltage
Ans: c

85. In a 3-phase synchronous motor, the negative phase sequence exists when the motor is
(a) supplied with unbalanced voltage
(b) under-loaded
(c) over-loaded
(d)     none of the above
Ans: a

86. In a synchronous motor, damper windings are provided on
(a) stator frame    
(b) rotor shaft
(c) pole faces
(d) none of the above
Ans: c

87. The induced e.m.f. in a synchronous motor working on leading power factor will be
(a) more than the supply voltage
(b) less than the supply voltage
(c) equal to the supply voltage
Ans: a

88. The effect of  increasing the load on a synchronous motor running with normal excitation is to
(a)     decrease both armature current and power factor
(6)     decrease armature current but increase power factor
(c) increase armature current but decrease power factor
(d) increase both its armature current and power factor
Ans: c

89. The net armature voltage of a synchronous motor is equal to the
(a) vector sum of Eb and V
(b) arithmetic sum of Eb and V
(c) arithmetic difference of Eb and V
(d) vector difference of Eh and V
Ans: d

90. The ratio of starting torque to running torque in a synchronous motor is
(a) zero
(b) one
(c) two
(d) infinity
Ans: a

91. In a synchronous motor, the magnitude of stator back e.m.f. Eb depends on
(a) load on the motor
(b) d.c. excitation only
(c) both the speed and rotor flux
(d) none of the above
Ans: b

92. A 3-phase synchronous motor is running clockwise. If the direction of its field current is reversed
(a)     the motor will stop
(b)     the motor continue to run in the same direction
(c) the winding of the motor will burn
(d) the motor will run in the reverse direction
(e) none of the above
Ans: b

93. The magnitude of field flux in a 3-phase synchronous motor
(a)     remains constant at all loads
(b)     varies with speed
(c) varies with the load
(d) varies with power factor
Ans: a

94. The torque angle, in a synchronous motor, is the angle between
(a) the supply voltage and the back e.m.f.
(b) magnetising current and back e.m.f.
(c) the rotating stator flux and rotor poles
(d) none of the above
Ans: c

95. Hunting in a synchronous motor cannot be due to
(a) windage friction
(b) variable load
(c) variable frequency
(d) variable supply voltage
Ans: a

96. By which of the following methods the constant speed of a synchronous motor can be changed to new fixed value ?
(a) By changing the supply frequency
(b) By interchanging any two phases
(c) By changing the applied voltage
(d) By changing the load.
Ans: a

97. In a synchronous motor, V-curves represent relation between
(a)     armature current and field current
(b)     power factor and speed
(c) field current and speed
(d) field current and power factor
Ans: a

98. In a 3-phase, 4-pole, 50 Hz synchronous motor, the frequency, pole number and load torque all are halved. The motor speed will be
(a)     3000 r.p.m.      
(b)     1500 r.p.m.
(c) 750 r.p.m.
(d) none of the above
Ans: b

99. A synchronous motor connected to infinite bus-bars has at constant full load, 100% excitation and unity power fac
tor. On changing the excitation only, the armature current will have
(a)     no change of power factor
(b)     lagging power factor with over-excitation
(c) leading power factor with under-excitation
(d) leading power factor with over-excitation
Ans: d

100.   Which of the following motors is non-self starting ?
(a)     D.C. series motor
(b)     synchronous motor
(c) Squirrel cage induction motor
(d) Wound round induction motor
Ans: b

101. In a synchronous motor it the back e.m.f. generated in the armature at noload is approximately equal to the applied voltage, then
(a) the motor is said to be fully loaded
(b) the torque generated is maximum
(c) the excitation is said to be zero per cent
(d) the excitation is said to be hundred per cent
Ans: d

102. In a synchronous motor, the damping winding is generally used to
(a) prevent hunting and provide the starting torque
(b) reduce the eddy currents
(c) provide starting torque only
(d) reduce noise level
(e) none of the above
Ans: a

103. If the field of a synchronous motor is underexcited, the power factor will be
(a) zero
(b) unity
(c) lagging
(d) leading
Ans: c

104. The back e.m.f. in the stator of a synchronous motor depends on
(a) number of poles
(b) flux density    
(c)     rotor speed
(d) rotor excitation
(e) none of the above
Ans: d

105.   The maximum value of torque that a synchronous motor can develop without losing its synchronism, is known as
(a)     slip torque
(b)     pull-out torque
(c) breaking torque
(d) synchronising torque
Ans: d

106. In a synchronous motor, the armature current has large values for
(a) high excitation only
(b) low excitation only
(c) both high and low excitation
(d) none of the above
Ans: c

107. Which of the following losses, in a synchronous motor, does not vary with load?
(a) Windage loss  
(b) Copper losses
(c) Any of the above
(d) None of the above
Ans: a

108. The size of a synchronous motor decreases with the increase in
(a) flux density
(b) horse power rating
(c) speed
(d) all of the above
Ans: a

109. Which of the following losses is not dissipated by the stator core surface in a synchronous motor ?
(a) Eddy current losses in the conductors
(b) Iron losses in the stator
(c) Copper losses in the slot portion of the conductors
(d) Windage losses
(e) None of the above
Ans: d

110. The duration of sudden snort-circuit test on a synchronous motor is usually about
(a)     one hour
(b)     one minute
(c) one second
(d) none of the above
Ans: c

Latest Synchronous Motors Objective type Questions for freshers

TOP 10 Synchronous Motors Interview Questions and Answers pdf free download




Real Time Synchronous Motors Interview Questions with Answers PDF

=> Also Read Synchronous Motors MCQs
1.  State the characteristic features of synchronous motor.
A.  the motor is not inherently self starting
B.   The speed of operation is always in synchronous with the supply frequency irrespective of load   conditions
C.   The motor is capable of operating at any power factor.

2.  In what way synchronous motor is different from other motors?
All dc and ac motors work on the same principle. Synchronous motor operates due to magnetic locking taking place between stator and rotor magnetic fields.
Synchronous Motor Interview Questions
3.  Name any two methods of starting a synchronous motors
•    By an extra 3 phase cage induction motor
•    By providing damper winding in pole phases
•    By operating the pilot excitor as a dc motor


4.  What is the effect on speed if the load is increased on a 3 phase synchronous motor?
The speed of operation remains constant from no load to maximum load in the motor operating at constant frequency bus bars.

5.  Why a synchronous motor is a constant speed motor.
Synchronous motor work on the principle of force developed due to the magnetic attraction established between the rotating magnetic field and the main pole feed. Since the speed of rotating magnetic field is directly proportional to frequency the motor operates at constant speed.

6. What is the phasor relation between induced emf and terminal voltage of a 3 phase  synchronous motor?
The rotating magnetic field is initially established by the prime source of supply V. The main field then causes an emf e to get induced in the 3 phase winding. Hence when the machine operates as a synchronous motor the emf phasor always lags the terminal voltage phasor by the load1torque angle   .

7. At what load angle is power developed in a synchronous motor becomes its maximum value ?
When its load angle   is equal to the impedance angle   .

8. What are V and inverted V curves of synchronous motor ?
The variation of magnitude of line current with respect to the field current is called V curve . The variation of power factor with respect to the field current is called inverted V curve.


9. What happens when the field current of a synchronous motor is increased beyond the normal value at constant input?
Increase in emf causes the motor to have reactive current in the leading direction. The additional leading reactive current causes the magnitude of line current, accompanied by the decrease in power factor.

10.Distinguish between synchronous phase modifier and synchronous condenser.
A synchronous motor used to change the power factor or power factor in the supply lines is called synchronous phase modifier.
A synchronous motor operated at no load with over excitation condition to draw large leading reactive current and power is called a synchronous condenser.

Latest Synchronous Motors Interview Questions for freshers and Experienced pdf